Skip to main content
  • Original Paper
  • Open access
  • Published:

Increased ACL direct insertion coverage provided more positive biomechanical effects on graft and bone tunnel during knee flexion: a simulation study

Abstract

Purpose

Flattened femoral tunnels were recently applied in anatomical single-bundle anterior cruciate ligament (ACL) reconstruction. Little is known about the biomechanical effect of such changes during knee flexion. The aim of the present simulation study was to assess the effect of altered ACL direct insertion coverage on the biomechanics of the graft and bone tunnel.

Methods

Five finite element (FE) models, including a round femoral tunnel and four progressively flattened rounded rectangular femoral tunnels, were established to represent the ACL reconstructions. In vivo knee kinematics data obtained from the validated dual fluoroscopic imaging techniques controlled the FE models to simulate lunge motions. The maximal principal stress of the graft and the volume of equivalent strain within 1000–3000 microstrain (V1000-3000) of the cancellous bone were subsequently calculated at 0°, 30°, 60° and 90° of knee flexion.

Results

A lower stress state on the graft and a more beneficial strain state on the cancellous bone were observed when the femoral tunnel better covered the ACL direct insertion. The average maximal principal stress of each model were 3.93 ± 0.60 MPa, 3.82 ± 0.54 MPa, 3.43 ± 0.44 MPa, 3.45 ± 0.44 MPa and 3.05 ± 0.43 MPa, respectively. The average V1000-3000 of the cancellous bone of each model were 179.06 ± 89.62 mm3, 221.40 ± 129.83 mm3, 247.57 ± 157.78 mm3, 282.74 ± 178.51 mm3 and 295.71 ± 162.59 mm3, respectively. Both the stress and strain values exhibited two peaks during the flexion simulation. The highest value occurred at 30° of flexion, and the second highest value occurred at 90° of flexion.

Conclusions

Increased ACL direct insertion coverage provided more positive biomechanical effects after anatomical single-bundle ACL reconstruction during knee flexion.

Introduction

In recent years, anatomical studies have shown that the native ACL femoral footprint includes direct and indirect insertion [14, 19]. Direct insertion is located in the anterior region of the footprint, consisting of dense collagen fibres directly attached to the bone. Indirect insertion is located in the posterior area of the footprint near the femoral articular cartilage, consisting of membrane-like tissue [8, 22]. The direct fibres from the ribbon-like direct insertion bore more than 80% of the total anterior ACL load during stability testing [18]. The single-bundle ACL reconstruction using a round femoral tunnel seems to not restore the insertion sites and the fibre arrangement of the native ACL entirely [13].

Since the anatomy of the native ACL is the basis for anatomical ACL reconstruction, investigators tried to change the shape of the femoral tunnel, such as rounded rectangular and rectangular [5, 16, 25, 27]. These tailoring tunnels were flatter than the traditional round tunnel, which were expected to better restore the insertion site and morphology of the native ACL [13]. To date, two potential benefits of using a flatter femoral tunnel in anatomical single-bundle ACL reconstruction exist. Firstly, cadaver experiments showed that a flattened femoral tunnel improves the stability of the knee joint [7, 24]. Secondly, an animal experiment showed that a flattened femoral tunnel accelerates tendon-bone healing in the early period after ACL reconstruction [32].

Based on the evidence above, changing the morphology of the ACL graft will affect its function biomechanically and biologically. Theoretically, different widths of ACL direct insertion result in different graft morphology and biomechanical behaviour. There is no doubt that knee joint flexion–extension activity is closely related to complications after ACL reconstruction, such as graft injury and bone tunnel enlargement [15, 30]. Understanding the biomechanical differences caused by surgical variation is imperative for postoperative rehabilitation. The strategy of joint motion should follow anatomical and biomechanical principles. However, previous biomechanical research on changing the tunnel diameter was mainly performed under in vitro static conditions. In multiple studies, graft volume, tunnel orientation and tibial tunnel shape were inconsistent and challenging to compare.

Finite element (FE) analysis is a powerful tool for assessing the biomechanics of the knee joint [1, 28, 29]. The advantage of such analysis is that it can combine in vivo kinematic data for joint motion simulation. Moreover, it can iteratively change the geometries while keeping the other parameters constant. This is impossible in cadaver experiments. This study aimed to evaluate the biomechanical effect of changing the coverage of ACL direct insertion via FE simulations. The hypothesis of this study was that increased ACL direct insertion coverage could improve the biomechanics of graft and bone tunnel during knee flexion.

Materials and methods

Surgical modelling

The right knee of a healthy volunteer (male; 26 years; body height 175 cm; body weight 65 kg; no history of knee injuries and systemic diseases) was imaged using computed tomography (CT) (SOMATOM Definition AS + ; Siemens) with a thickness of 0.6 mm. Three-dimensional models of the femur and tibia were calculated from the CT images in Mimics (v19.0, Materialize NV, Leuven, BE). The anterior ridge and medial intercondylar ridge were identified and used to determine the ACL tibial footprint on the tibial model. The tibial attachment point was identified as the midpoint of the double bundle of the ACL on the tibial footprint (Fig. 1A) [1]. The lateral intercondylar ridge was identified and used to determine the ACL direct insertion on the femoral model [31]. The femoral attachment point was the midpoint of the lateral intercondylar ridge, near the centre of the ACL direct insertion (Fig. 1B).

Fig. 1
figure 1

A Identification of the tibial footprint of the ACL (a anterior ridge; b medial intercondylar ridge; purple region posterolateral bundle of the ACL; blue region anteromedial bundle of the ACL; yellow point tibial attachment point). B Identification of the femoral footprint of the ACL (orange region direct ACL insertion; green region indirect ACL insertion; red line lateral intercondylar ridge; yellow point femoral attachment point). C Positional relationship among the tunnels and the landmarks on the ACL femoral footprint

The tibial tunnel orientation was made at 15° in the front view and 55° in the sagittal view. The tibial tunnel was a traditional round tunnel with a diameter of 8 mm. The femoral tunnel orientation was made through the anteromedial portal technique, perpendicular to the medial surface of the lateral condyle. The femoral tunnel was first created as a traditional round tunnel with a diameter of 8 mm. Then, the tunnel's diameter was gradually adjusted with the central point unchanged to create four rounded rectangular femoral tunnels parallel to the lateral intercondylar ridge. The long-axis diameter of the femoral tunnel was the only variable. The tunnel with the largest long-axis diameter completely covered the direct insertion of the ACL (Fig. 1C). The sizes of the various femoral tunnel apertures are shown in Fig. 2.

Fig. 2
figure 2

Sizes of the various tunnel apertures created in the femur

The length of the rectangular region was set as 2 mm, 4 mm, 6 mm and 8 mm. The radius of the rounded rectangle was calculated using the following equation: \(S=L\times 2R+\pi \times {R}^{2}\), where the constant cross sectional area \(S=\pi \times ({\frac{8}{2})}^{2}\), \(L\) is the length of the rectangular region and \(R\) is the radius of the rounded rectangle. The grafts measured 20 cm in depth into the femoral and tibial tunnels and were constructed as single, soft cylindrical solids (Fig. 3). All modelling procedures were performed using SolidWorks (v2018, Dassault Systemes, Massachusetts, USA).

Fig. 3
figure 3

Morphology of different grafts after ACL reconstruction with different femoral tunnels

In vivo kinematic data

Methods of kinematic data acquisition and coordinate system (CS) establishment were the same as the previous study [29]. The experimental processes are shown as follows. First, the knee of the subject was simultaneously imaged by two fluoroscopes (BV Pulsera; Philips) when a lunge motion was performed. Then, the fluoroscopic images were positioned in the imaging planes based on the projection geometry of the fluoroscopes in MATLAB (R2013a; MathWorks). Next, local femoral CS (floating CS) and tibial CS (fixed CS) were established on the CT-based models of the femur and tibia. The models were independently manipulated in six degrees of freedom (6DOF) to match the outlines of the fluoroscopic images (30°, 60° and 90° knee flexion). Finally, the 6DOF changes in knee flexion were calculated according to the rotation matrix (floating CS relative to fixed CS) using MATLAB after the matching procedure.

FE models of the knee joint

Simulations were performed in Abaqus (v2018; Dassault Systèmes SE, Vélizy-Villacoublay, FR). To accurately simulate the material properties of bone tunnels, the femur consisted of cortical (2 mm thick from the outer bone surface) and cancellous bones [28]. The tibia and cortical bone of the femur were considered shells and defined as rigid bodies. The cancellous bone of the femur was defined as isotropic linear elastic with Young’s modulus E = 389 MPa and Poisson’s ratio v = 0.3 [4]. The grafts were defined as nearly incompressible, transversely isotropic hyperelastic neo-Hookean materials based on the following strain-energy function: \(\Psi\)=\(\frac{1}{2D}\) ln(J)2 + C1(\({\overline{{I }_{1}}}^{2}-3\)) + F2(\(\lambda\)), where J is the determinant of the deformation gradient tensor, \(\overline{{I }_{1}}\) is the first invariant of the modified Cauchy-Green tensor, F2 is the isochoric part of the strain-energy function depending on the collagen fibres, \(\lambda\) is the stretch of the fibre, C1 is the neo-Hookean constant, and D is the inverse of the bulk modulus k = 1/D (C1 = 1.95, D = 0.00683) [20].

A free meshing technique was used for the cortical bone and the tibia (four-node 3D bilinear rigid quadrilateral element; element type: R3D4), the cancellous bone (four-node linear tetrahedron element; element type: C3D4) and the graft (eight-node linear hexahedral elements with hourglass control; element type: C3D8RH). A mesh sensitivity analysis was performed by stepwise upsizing the mesh size [21]. The convergence tolerance was set as a stress variation within 5% from the previous model with higher mesh density. The mesh size of grafts was between 1.0 and 1.2 mm. The mesh size of cancellous bone was 1.4 mm, and mesh refinement was applied to 1.0 mm around the tunnel entrances. The graft and cancellous bone models included an average of 4000-plus nodes with 3000-plus elements and 57,000-plus nodes with 306,000-plus elements, respectively.

Boundary and loading conditions & simulation outputs

Bonded contact between the cortical bone and the cancellous bone was defined. Bonded contact between the graft and the internal surface of the femoral cancellous bone tunnel was defined. Frictionless contact between the graft and tibial tunnel and between the graft and femoral cortical bone tunnel was defined as suggested by a previous study [28]. Two steps of loading conditions were implemented. First, the femur and tibia were fixed, and an initial graft tension of 50 N was applied on the end surface of the graft along the tibial tunnel direction. Second, the tibia and the portion of the graft in the tibial tunnel were fixed, and the femur was translated and rotated according to the 6DOF calculation relative to the femoral CS described above (Fig. 4).

Fig. 4
figure 4

The constraint and load conditions applied in the simulation

The maximum principal stress on the graft and the equivalent strain of the cancellous bone around the tunnel entrances were selected as the biomechanical indicators and subsequently calculated. The strain range in the 1000–3000 microstrain region was considered beneficial for bone modelling [6]. The equivalent strain was defined as \(\varepsilon =\sqrt{\frac{1}{2}[{\left({\varepsilon }_{1}-{\varepsilon }_{2}\right)}^{2}+{\left({\varepsilon }_{1}-{\varepsilon }_{3}\right)}^{2}+{\left({\varepsilon }_{2}-{\varepsilon }_{3}\right)}^{2}]}\), where \({\varepsilon }_{1}\), \({\varepsilon }_{2}\) and \({\varepsilon }_{3}\) are three principal strains [12]. The volume of equivalent strain within 1000–3000 microstrain (V1000-3000) on the cancellous bone was recorded (Fig. 5).

Fig. 5
figure 5

A The maximal principal stress on the graft was calculated for each model during flexion simulation; B The equivalent strain on the cancellous bone around the tunnel entrances; C The volume of equivalent strain within 1000–3000 microstrain on the cancellous bone was recorded

Results

Maximal principal stress

The maximal principal stress of the graft appeared near the entrance to the femoral tunnel at all flexion angles. Two peaks of stresses were found during the flexion simulation. The highest value occurred at 30° of flexion, and the second highest value occurred at 90° of flexion. Compared to the round tunnel, decreased maximal principal stresses were found at all angles when the tunnel size became flattened. Through the whole range of motion, the average maximal principal stress of each model was 3.93 ± 0.60 MPa, 3.82 ± 0.54 MPa, 3.43 ± 0.44 MPa, 3.45 ± 0.44 MPa and 3.05 ± 0.43 MPa, respectively (Fig. 6A; Table 1).

Fig. 6
figure 6

A Comparison of the average maximal principal stress on the graft among the different tunnel sizes during knee flexion. B Comparison of the average V1000-3000 on cancellous bone among the different tunnel sizes during knee flexion

Table 1 The maximal principal stress (MPa) of the graft with different femoral tunnel sizes at various flexion angles

Equivalent strain

The distribution of equivalent strain on the cancellous bone for each model is displayed in Fig. 7.

Fig. 7
figure 7

Distribution of equivalent strain on the cancellous bone around the tunnel entrances

The V1000-3000 on the cancellous bone has two peaks during the flexion simulation. The largest V1000-3000 occurred at 30° of flexion, and the second largest V1000-3000 occurred at 90° of flexion. Increased V1000-3000 values were found when the tunnel size generally became flattened. Through the whole range of motion, the average V1000-3000 of the cancellous bone of each model was 179.06 ± 89.62 mm3, 221.40 ± 129.83 mm3, 247.57 ± 157.78 mm3, 282.74 ± 178.51 mm3 and 295.71 ± 162.59 mm3, respectively (Fig. 6B; Table 2).

Table 2 The volume of equivalent strain within 1000–3000 microstrain (mm3) on the cancellous bone with different femoral tunnel sizes at various flexion angles

Discussion

The most important finding of the present study is that increasing the ACL direct insertion coverage positively affects the biomechanics of the graft and bone tunnel after anatomical single-bundle ACL reconstruction during knee flexion. Graft stresses and strains around the bone tunnels can explain these findings. From the perspective of the flexion angle, the maximal principal stress of the graft and the V1000-3000 of cancellous bone around the tunnel increased first. Then it decreased from 0° to 60° of flexion when the maximum force was reached at 30° of flexion. Both values increased when the knee joint was at 90° of flexion. From the perspective of tunnel diameter, changing the femoral tunnel size had obvious biomechanical differences. Increased ACL direct insertion coverage results in larger V1000-3000 of cancellous bone on the femoral tunnel entrances and a lower maximal principal stress on the ACL graft.

Previous biomechanical studies have clarified that direct fibres lead to higher loads than indirect fibres when restraining anterior tibial translation and rotation [10, 18]. Considering that traditional ACL reconstruction using a round femoral tunnel breaks the native ACL attachment and histologic structures, it may be necessary to use reasonable tunnel-shaping methods to overcome this limitation of the surgery from the anatomical and biomechanical point of view. Recently, a biomechanical study of cadaveric specimens demonstrated that both single bundle ribbon-like and round grafts used in ACL reconstruction restored the kinematics of the intact knee at time zero [3]. Since the recovery of the knee joint after ACL reconstruction takes time, the differences in graft stress and bone tunnel strain caused by tunnel sizes may be potential factors affecting long-term clinical outcomes.

Orthopaedic surgeons have used the rounded rectangular femoral tunnel in primary or revision ACL reconstruction, yielding good clinical outcomes [7, 17, 23]. The long-axis diameters of the rounded rectangle dilator varied from 9 to 12 mm in surgery. Different femoral tunnels determine the different morphologies and volumes of grafts, which may affect the results of surgical reconstruction. A rounded rectangular femoral tunnel led to an anatomical femoral insertion with a flat tendon graft, providing better fibre arrangement and resembling the original ACL. Moreover, stress concentration on the graft was thought to be closely related to graft injuries after surgery [9]. This study indicated that the maximal principal stress on the graft is near the entrance of the femoral tunnel, which is the most frequent location of graft failure in autograft [11]. The results also showed that the trends of change in maximal principal stress of the graft decreased when the tunnel became flatter. Thus, increasing the long-axis diameter of the femoral tunnel when the graft volume is constant may represent an effective strategy in anatomical single-bundle ACL reconstruction.

Bone tunnel enlargement is a common phenomenon after ACL reconstruction caused by mechanical and biological factors [30]. The bone tunnel and reconstructed ligament undergo repetitive mechanical changes with knee joint extension and flexion. A suitable mechanical environment is beneficial to bone modelling and tendon-bone healing. A previous study demonstrated that the strain value inside the bones was an essential factor determining bone formation or resorption in response to mechanical loading [6]. The bone modelling process is switched when bone strains exceed 1000 microstrain. Repeated bone strains cause microscopic fatigue damage in bone with an operational threshold strain range greater than 3000 microstrain [6]. Researchers also used the strain around the bone tunnel to account for bone tunnel enlargement after ACL reconstruction in FE simulation [2]. The current results showed that the volume of cancellous bone strain within 1000–3000 microstrain increased as the tunnel flattened. A previous study showed that the CT value of the femoral bone tunnel was significantly higher for the rounded rectangular tunnel than the round tunnel [26]. This observation was consistent with the current results, as increasing the long-axis diameter of the femoral tunnel in ACL reconstruction might be beneficial to bone modelling as it results in a lower tunnel enlargement ratio.

This study has several limitations. Only a few flexion angles were selected, and the entire range of motion was not analysed. Because the knee joint is activity-dependent, other functional activities, such as walking and ascending stairs, may cause different biomechanical environments at the bone tunnel and the ACL graft. In addition, rigid contact between the graft and bone tunnel was applied in the simulation with no consideration of relative motion occurring between the graft and the tunnel wall, which was not entirely consistent with clinical practice. Furthermore, the present study was conducted with a subject-specific model. The tunnel sizes in this study included the maximum width of clinical application but not the maximum width of other individuals. Further study should consist of other subjects and tunnel sizes to determine whether this is a typical result.

Conclusions

The results of this study confirm that increased ACL direct insertion coverage provided a more positive effect during knee flexion after anatomical single-bundle ACL reconstruction, resulting in a lower stress state on the ACL graft and a more beneficial strain state of cancellous bone on femoral tunnel entrances. The present study is meaningful as it provides biomechanical evidence for clinical practice.

Availability of data and materials

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Abbreviations

ACL:

Anterior cruciate ligament

FE:

Finite element

CT:

Computed tomography

CS:

Coordinate system

6DOF:

Six degrees of freedom

V1000-3000 :

Volume of equivalent strain within 1000–3000 microstrain

References

  1. Bae JY, Kim GH, Seon JK, Jeon I (2016) Finite element study on the anatomic transtibial technique for single-bundle anterior cruciate ligament reconstruction. Med Biol Eng Compu 54:811–820

    Article  CAS  Google Scholar 

  2. Cheng R, Wang H, Dimitriou D, Jiang Z, Cheng CK, Tsai TY (2022) Central femoral tunnel placement can reduce stress and strain around bone tunnels and graft more than anteromedial femoral tunnel in anterior cruciate ligament reconstruction. Int J Numer Method Biomed Eng 38:e3590

    Article  PubMed  Google Scholar 

  3. Delaloye JR, Hartog C, Blatter S, Schläppi M, Müller D, Schwenke T et al (2023) Biomechanical comparison of anterior cruciate ligament reconstruction using a single-bundle round or ribbon-like hamstring tendon graft. Am J Sports Med 51:1162–1170

    Article  PubMed  Google Scholar 

  4. ElSheikh HF, MacDonald BJ, Hashmi MSJ (2003) Finite element simulation of the hip joint during stumbling: a comparison between static and dynamic loading. J Materials Process Technol 143:249–255

    Article  Google Scholar 

  5. Fink C, Smigielski R, Siebold R, Abermann E, Herbort M (2020) Anterior cruciate ligament reconstruction using a ribbon-like graft with a c-shaped tibial bone tunnel. Arthrosc Tech 9:e247–e262

    Article  PubMed  PubMed Central  Google Scholar 

  6. Frost HM (2004) A 2003 update of bone physiology and wolff’s law for clinicians. Angle Orthod 74:3–15

    PubMed  Google Scholar 

  7. Herbort M, Tecklenburg K, Zantop T, Raschke MJ, Hoser C, Schulze M et al (2013) Single-bundle anterior cruciate ligament reconstruction: biomechanical cadaveric study of a rectangular quadriceps and bone-patellar tendon-bone graft configuration versus a round hamstring graft. Arthroscopy 29:1981–1990

    Article  PubMed  Google Scholar 

  8. Iwahashi T, Shino K, Nakata K, Otsubo H, Suzuki T, Amano H et al (2010) Direct anterior cruciate ligament insertion to the femur assessed by histology and 3-dimensional volume-rendered computed tomography. Arthroscopy 26:S13-20

    Article  PubMed  Google Scholar 

  9. Kang K, Bae TS (2017) Effect of femoral tunnel positions on graft stress in outside-in ACL reconstruction surgery during continuous knee motion: a simulation study. Int J Med Robot 13:e1817

    Article  Google Scholar 

  10. Kawaguchi Y, Kondo E, Takeda R, Akita K, Yasuda K, Amis AA (2015) The role of fibers in the femoral attachment of the anterior cruciate ligament in resisting tibial displacement. Arthroscopy 31:435–444

    Article  PubMed  PubMed Central  Google Scholar 

  11. Magnussen RA, Taylor DC, Toth AP, Garrett WE (2012) ACL graft failure location differs between allografts and autografts. Sports Med Arthrosc Rehabil Ther Technol 4:22

    Article  PubMed  PubMed Central  Google Scholar 

  12. Mellal A, Wiskott HWA, Botsis J, Scherrer SS, Belser UC (2004) Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data. Clin Oral Implant Res 15:239–248

    Article  CAS  Google Scholar 

  13. Middleton KK, Muller B, Araujo PH, Fujimaki Y, Rabuck SJ, Irrgang JJ et al (2015) Is the native ACL insertion site “completely restored” using an individualized approach to single-bundle ACL-R? Knee Surg Sports Traumatol Arthrosc 23:2145–2150

    Article  CAS  PubMed  Google Scholar 

  14. Mochizuki T, Fujishiro H, Nimura A, Mahakkanukrauh P, Yasuda K, Muneta T et al (2014) Anatomic and histologic analysis of the mid-substance and fan-like extension fibres of the anterior cruciate ligament during knee motion, with special reference to the femoral attachment. Knee Surg Sports Traumatol Arthrosc 22:336–344

    Article  PubMed  Google Scholar 

  15. Musahl V, Karlsson J (2019) Anterior cruciate ligament tear. N Engl J Med 380:2341–2348

    Article  PubMed  Google Scholar 

  16. Nakase J, Toratani T, Kosaka M, Ohashi Y, Numata H, Oshima T et al (2016) Technique of anatomical single bundle ACL reconstruction with rounded rectangle femoral dilator. Knee 23:91–96

    Article  PubMed  Google Scholar 

  17. Nakase J, Takata Y, Shimozaki K, Asai K, Yoshimizu R, Kimura M et al (2021) Clinical study of anatomical ACL reconstruction using a rounded rectangular dilator. BMC Musculoskelet Disord 22:38

    Article  PubMed  PubMed Central  Google Scholar 

  18. Nawabi DH, Tucker S, Schafer KA, Zuiderbaan HA, Nguyen JT, Wickiewicz TL et al (2016) ACL fibers near the lateral intercondylar ridge are the most load bearing during stability examinations and isometric through passive flexion. Am J Sports Med 44:2563–2571

    Article  PubMed  Google Scholar 

  19. Oka S, Schuhmacher P, Brehmer A, Traut U, Kirsch J, Siebold R (2016) Histological analysis of the tibial anterior cruciate ligament insertion. Knee Surg Sports Traumatol Arthrosc 24:747–753

    Article  PubMed  Google Scholar 

  20. Peña E, Calvo B, Martínez MA, Doblaré M (2006) A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint. J Biomech 39:1686–1701

    Article  PubMed  Google Scholar 

  21. Robbins SM, Raymond N, Abram F, Pelletier JP, Martel-Pelletier J (2016) The effects of knee joint kinematics on anterior cruciate ligament injury and articular cartilage damage. Comput Methods Biomech Biomed Engin 19:493–506

    Article  Google Scholar 

  22. Sasaki N, Ishibashi Y, Tsuda E, Yamamoto Y, Maeda S, Mizukami H et al (2012) The femoral insertion of the anterior cruciate ligament: discrepancy between macroscopic and histological observations. Arthroscopy 28:1135–1146

    Article  PubMed  Google Scholar 

  23. Shao J, Niu X, Wang Y, Ao Y (2020) Novel application of a rounded-rectangular bone tunnel in revision ACL reconstruction: a report of 2 patients. Orthop J Sports Med 8:2325967120944901

    PubMed  PubMed Central  Google Scholar 

  24. Suzuki T, Shino K, Otsubo H, Suzuki D, Mae T, Fujimiya M et al (2014) Biomechanical comparison between the rectangular-tunnel and the round-tunnel anterior cruciate ligament reconstruction procedures with a bone-patellar tendon-bone graft. Arthroscopy 30:1294–1302

    Article  PubMed  Google Scholar 

  25. Tachibana Y, Shino K, Mae T, Iuchi R, Take Y, Nakagawa S (2019) Anatomical rectangular tunnels identified with the arthroscopic landmarks result in excellent outcomes in ACL reconstruction with a BTB graft. Knee Surg Sports Traumatol Arthrosc 27:2680–2690

    Article  PubMed  Google Scholar 

  26. Takata Y, Nakase J, Numata H, Oshima T, Tsuchiya H (2016) Computed tomography value and tunnel enlargement of round and rounded rectangular femoral bone tunnel for anterior cruciate ligament reconstruction. Arch Orthop Trauma Surg 136:1587–1594

    Article  PubMed  Google Scholar 

  27. Uchida R, Shiozaki Y, Tanaka Y, Kita K, Amano H, Kanamoto T et al (2019) Relationship between bone plug position and morphological changes of tunnel aperture in anatomic rectangular tunnel ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 27:2417–2425

    Article  PubMed  Google Scholar 

  28. Wan C, Hao Z (2018) Does the graft-tunnel friction influence knee joint kinematics and biomechanics after anterior cruciate ligament reconstruction? A finite element study. Comput Methods Biomech Biomed Engin 21:278–286

    Article  PubMed  Google Scholar 

  29. Xiao Y, Ling M, Liang Z, Ding J, Zhan S, Hu H et al (2021) Dual fluoroscopic imaging and CT-based finite element modeling to estimate forces and stresses of grafts in anatomical single-bundle ACL reconstruction with different femoral tunnels. Int J Comput Assist Radiol Surg 16:495–504

    Article  PubMed  PubMed Central  Google Scholar 

  30. Yue L, DeFroda SF, Sullivan K, Garcia D, Owens BD (2020) Mechanisms of bone tunnel enlargement following anterior cruciate ligament reconstruction. JBJS Rev 8:e0120

    Article  PubMed  Google Scholar 

  31. Zauleck MK, Gabriel S, Fischmeister MF, Hirtler L (2014) Origin of the anterior cruciate ligament and the surrounding osseous landmarks of the femur. Clin Anat 27:1103–1110

    Article  PubMed  Google Scholar 

  32. Zhao F, Hu X, Zhang J, Shi W, Ren B, Huang H et al (2019) A more flattened bone tunnel has a positive effect on tendon–bone healing in the early period after ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 27:3543–3551

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This project was supported by the National Natural Science Foundation of China (No. 12272164), Science and Technology Program of Guangzhou, China (No.202102080570) and Innovation Programme among Guangdong, Hong Kong and Macao (No. 2021A0505110011).

Author information

Authors and Affiliations

Authors

Contributions

YX and ZL proposed the conception and drafted the manuscript. SS acquired the data. FL analysed and interpreted the data. BC and HH revised the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Bin Chen.

Ethics declarations

Ethics approval and consent to participate

This study was approved by the Institutional Review Board of Shanghai Jiao Tong University (ChiCTR-RPC-17013341). Informed consent was obtained from the participant included in the study.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Xiao, Y., Liang, Z., Shen, S. et al. Increased ACL direct insertion coverage provided more positive biomechanical effects on graft and bone tunnel during knee flexion: a simulation study. J EXP ORTOP 10, 108 (2023). https://doi.org/10.1186/s40634-023-00677-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40634-023-00677-x

Keywords