Biomechanical comparison of vertical suture techniques for repairing radial meniscus tear

Abstract

Purpose

The aim of this study was to (1) develop suture techniques in repairing radial meniscal tear; (2) to compare the biomechanical properties of the proposed repair techniques with the conventional double horizontal technique.

Methods

Thirty-six fresh-frozen porcine medial menisci were randomly assigned into four groups and a complete tear was made at the midline of each meniscus. The menisci were subsequently repaired using four different repair techniques: double vertical (DV), double vertical cross (DVX), hybrid composing one vertical and one horizontal stitch, and conventional double horizontal (DH) suture technique with suturing parallel to the tibia plateau. The conventional double horizontal group was the control. The repaired menisci were subjected to cyclic loading followed by the load to failure testing. Gap formation and strength were measured, stiffness was calculated, and mode of failure was recorded.

Results

Group differences in gap formation were not statistically significant at 100 cycles (p = .42), 300 cycles (p = .68), and 500 cycles (p = .70). A trend was found toward higher load to failure in DVX (276.8 N, p < .001), DV (241.5 N, p < .001), and Hybrid (237.6 N, p < .001) compared with DH (148.5 N). Stiffness was also higher in DVX (60.7 N/mm, p < .001), DV (55.3 N/mm, p < .01), and Hybrid (52.1 N/mm, p < .01), than DH group (30.5 N/mm). Tissue failure was the only failure mode observed in all specimens.

Conclusion

Our two proposed vertical suture techniques, as well as the double vertical technique, had superior biomechanical properties than the conventional technique as demonstrated by higher stiffness and higher strength.

Background

The knee meniscus plays a key role in joint lubrication, shock absorption, load-bearing and load distribution, thus it often withstands different forms of forces and is susceptible to injuries [2, 3, 26, 42]. Radial meniscal tear has increasingly become common, particularly in sports traumatology [28]. In the last century, partial or total meniscectomy – removing the damaged meniscal tissue - was the gold standard to treat meniscal tear [14, 19]. However, joint deterioration and early onsite of knee osteoarthritis were reported in studies following up patients underwent meniscectomy treatment [25]. As a result, it is widely accepted today that treatment of meniscus tear should preserve the knee meniscal tissue as much as possible [18, 22, 23, 28].

The inside-out/outside-in technique passing horizontal stitches has been commonly used today to treat various types of meniscal tear, however, it is still inconclusive whether this method is the optimal approach to repair radial meniscal tear [4, 6, 20, 24, 27, 33]. In light of the limitations of the traditional inside-out double horizontal suture used for repairing radial tears [7], novel repair approaches using horizontal suture orientations were developed and tested. For example, the horizontal butterfly technique developed by Günes et al. decreases the amount of displacement but yields a similar failure load compared to the standard horizontal loop [4]. Solitro et al. reported that their reinforced repair technique has a higher failure load than the standard repair technique with two parallel sutures [27]. Meanwhile, suture techniques deploying a vertical orientation are developed and compared to techniques using horizontal stiches [10, 16]. The single loop vertical suture, a technique developed by Beamer et al. [6], was reported to be superior in strength than the single loop horizontal suture in repairing complete radial tear. However, Lemos et al. reported that the vertical suture has a significantly lower failure load than the inside-out parallel suture [16]. As no consensus on the best approach to repairing radial meniscus tear has been made, researchers and practitioners are calling for the development of novel repair techniques and studies that compare the performance between different techniques so that evidence-based decisions on the optimal approach can be made [8, 11, 13, 40].

Furthermore, the traditional all-inside device is only able to pass horizontally suture and deploy anchors at the meniscal peripheries. As a result, the suture cannot fully encircle the tear and failure at the anchors compromises the repair [6, 24, 35]. The invention of a novel suture passer, which was used in this study, solved this problem, as it enables passing suture vertically from the under-surface of the meniscus and allows easy adjustment of the alignment of sutures relative to the circumferential fibrils.

In light of the gap in research evidence and the advancement of medical device used for orthopedic surgery, we proposed two suture techniques for repairing radial meniscal tear: the double vertical cross and the hybrid suture techniques. The double vertical cross consists of two vertical stitches forming a cross. Since it is generally more challenging to stitch vertically than horizontally, we combined one vertical and one horizontal stitches in the hybrid suture technique. Compared to the abovementioned studies, our proposed two approaches deploy vertical sutures perpendicular to the tibia and suture configurations different from the other vertical suture techniques. Additionally, we included the double vertical parallel technique in our study, which enables a more systematic comparison of vertical suture orientation to the traditional horizontal suture technique.

The objective of this study was to assess the biomechanical properties, including gap formation, strength, and stiffness, of the three vertical two-stitch suture repair techniques compared with the traditional double horizontal suture technique in complete radial tear of the medial menisci. We hypothesized that all three techniques - double vertical cross, double vertical, and hybrid composing one vertical and horizontal strand - would offer better fixation and primary stability in the repair of complete radial meniscus tear. Vertically oriented stitches contribute to the stability of repaired construct more than horizontal stitches.

Materials and methods

Specimen preparation and suture techniques

We conducted an in vitro biomechanical study on fresh-frozen size-equivalent porcine medial menisci. A total of 36 specimens were harvested intact from adult hogs by resecting the tissue at the meniscoscapular junction and the two insertional ligaments. All the menisci were inspected and had no macroscopic signs of meniscal tear or degeneration. The resected menisci were thawed 5 h at room temperature (23–25 degree Celsius), and then wrapped with normal saline soaked gauze before testing. Radial tears were created at the meniscal mid-body equidistant from the anterior and posterior horns with a No. 11 surgical blade. The tears extended from the central margin to 1 mm from the peripheral meniscus rim.

After preparing the menisci with tears, the 36 specimens were randomly assigned into four groups to be repaired using different techniques: double horizontal mattress (simplified as “DH”) (n = 9), double vertical mattress (“DV”) (n = 9), double vertical cross (“DVX”) (n = 9), and Hybrid (n = 9). In the DH group (Fig. 1a), the meniscal tear was repaired with two horizontal loops at a distance of 5 mm on either side of the tear. The loop on superior level was placed 4 mm from the meniscal rim and the inferior loop was stitched 6 mm from the meniscal rim. The tested menisci in DV group were repaired with two parallel sutures at 5 mm from the tear and 4 and 6 mm from the rim. In addition, the orientation of the two loops are perpendicular to the bottom surface (Fig. 1b). In the DVX group, vertically oriented sutures crossed each other and were stitched at the same fixation points as in the DV group (Fig. 1c). The Hybrid technique comprised one horizontal loop and one vertical loop (Fig. 1d). The vertical loop was stitched in vertical orientation with a distance of 5 mm from the tear and 3 mm from the rim. The horizontal loop was placed in horizontal orientation with a distance of 5 mm from the tear and 9 mm from the rim.

Fig. 1
figure 1

a Scorpion (top) and Micro SutureLasso with different curvatures (bottom) meniscus repair devices used in the study; b Double vertical cross repair with the Scorpion device; c Double horizontal repair with the Micro SutureLasso device; c mechanical testing set up

All the vertical stitches were made in this study using the Knee Scorpion device (Arthrex, North Naples, FL) (Fig. 1a top). All the horizontal stitches were made with the Micro SutureLasso device (Arthrex, North Naples, FL) (Fig. 2a bottom). Same suture material was used (2–0 Ultrabraid, Smith&Nephrew, Andover, Massachusetts). Knee Scorpion (Arthrex, North Naples, FL) is a novel all-inside device using an articulated jaw to hold the meniscus and pass the suture vertically.

Fig. 2
figure 2

Illustration of meniscus repair techniques: a double horizontal technique, b double vertical technique, c double vertical cross technique, d hybrid technique

All specimens were tied by hands in an open fashion. Four square knots were tied with four throws. Once tied, the radial tear was completed by extending the tear through the meniscal rim. Before cyclic testing, each repaired specimen was inspected for any suture or tissue damage during the repair process. Specimens with damaged suture or unsecured knots were discarded.

Cyclic load testing

The repaired menisci’s two ends were stitched with baseball sutures using 5–0 Ethibond (Ethicon Inc., Johnson&Johnson) and then securely fastened to the universal tissue clamps with texture surface to prevent tissue slippage. The repaired menisci were aligned perpendicular to the tear, subsequently mounted to a mechanical testing system (Instron E1000, Instron, Norwood, Massachusetts) (Fig. 1d). During the pilot testing, specimens with the above-described roughening technique were tested and confirmed with negligible slippage at the interface between tissue and clamps.

The primary outcomes of our study were the ultimate failure load, stiffness and displacement during cyclic loading. After a preload of 2 N was applied to the specimen, cyclic loading from 5 to 20 N was performed at a frequency of 1 Hz and a crosshead velocity of 12.5 mm/s [6, 24, 35, 39, 41]. The load and frequency were chosen based on previous studies and reflective of in vivo post-operational rehabilitation [5, 6, 9, 12, 28, 29, 35, 37, 45, 46]. Specimens underwent 900 submaximal loading cycles and the Instron device was programed to pause 45 s at 0, 100, 300, 500 cycles to enable data collection and normal saline was sprayed to keep the specimens moist. The gap formation (displacement) was measured by the relative position of actuators. Both displacement and its corresponding load were recorded continuously by the computer program (Wavematrix; Instron, Norwood, MA). The gap formation was measured and recorded as the average distance across the tear at 12.5 N at 0, 100, 300, and 500 cycles. Cycle 0 served as the reference point for reporting the displacement of subsequent cycles 100, 300, and 500. After completion of cyclic loading, load to failure testing was performed at a rate of 3.15 mm/s. Stiffness as the linear region of the load-displacement curve was calculated. The mode of failure was carefully inspected and recorded. Three possible failure modes were tissue failure (pulled through by suture), suture failure (breakage), and knot failure (knot slippage).

Statistical analysis

A pilot testing of three specimens per group was performed and the effect size of 0.6 was determined from the load to failure pilot data. Power analysis using that effect size was calculated using G*Power (version 3.1.9.2) [17]. Nine specimens per group were determined to be adequate to detect a 20% change in the load to failure at 80% power. One-way analysis of variance (ANOVA) with post hoc Tukey analysis was performed to assess differences in the load to failure and stiffness across the four groups and between any two groups. Two-way ANOVA was performed at different cycles (100, 300, and 500 cycles) to test the differences between the four groups and between cycles. Data analysis was performed using R (Version 3.22) [R core Team, 2015]. All comparisons were two-tailed and a P value <.05 was considered statistically significant.

Results

The comparison of the primary outcomes – the ultimate failure load, stiffness, and displacement during cyclic loading – between the four groups were summarized in Table 1.

Table 1 Load to failure, stiffness and displacement results for the 4 repair techniques

Ultimate failure load

All data (displacement, failure load, and stiffness) were distributed normally (p > .05 for all cases). Statistically significant difference was observed when comparing the failure load across all groups (p < .001). As shown in Fig. 3, the DV (241 ± 30.3 N, p < .001), the DVX (276.8 ± 39.5 N, p < .001) and Hybrid (237.6 ± 25.2 N, p < .001) groups had significantly higher average ultimate failure load compared to the DH group (148.5 ± 22.3 N). Furthermore, the average failure load of the DVX group is significantly higher than that of the Hybrid group by 39.3 N (p < .01). However, no significant differences in the average failure load were detected between the DV, DVX and Hybrid groups.

Fig. 3
figure 3

Load to failure depicted for all four repair groups. * Significantly different from Double Horizontal. ** Significantly different from Hybrid and Double Horizontal

Stiffness

Similarly, statistically significant difference in stiffness was observed across all groups (p < .001). Shown in Fig. 4, all the DVX (60.7 ± 13.6 N/mm, p < .001), Hybrid (52.1 ± 8.6 N/mm, p < .01) and the DV (55.3 ± 17.0 N/mm, p < .01) groups had significantly higher average stiffness than the DH group (30.5 ± 7.2 N/mm). However, even though the DVX group had higher average of stiffness than the Hybrid and DV groups, the differences were not significant.

Fig. 4
figure 4

Stiffness depicted for all four repair groups. * Significantly different from double horizontal

Displacement during cyclic loading

In Fig. 5, we observed a trend of larger displacement with increased cycles of loading, irrespective of the suturing techniques. At 100, 300 and 500 cycles, the average displacement after cyclic loading in the Hybrid group was always the largest among the four groups. In contrast, the average displacement in the DV group was always the smallest among the four groups. However, the group differences did not reach statistical significance at 100 cycles (p = .42), at 300 cycles (p = .68), and at 500 cycles (p = .70).

Fig. 5
figure 5

Displacement after 100, 300, and 500 cycles depicted across four repair groups

Mode of failure

Tissue failure was observed across all specimens tested, and none of the failure resulted from suture or knot rupture.

Discussion

In this study, we found that the three vertical suture techniques showed significantly higher failure load and stiffness when compared with double horizontal suture technique in the repair of complete radial tear of medial meniscus. Therefore, the results of our study support our hypotheses that all three meniscus repair techniques were biomechanically superior to the conventional double horizontal suture technique.

The conventional inside-out and outside-in approaches can only pass horizontal sutures that are parallel to the tibia plateau. As a result, previous studies also reported that the inside-out/outside-in double horizontal sutures were associated with additional surgical incision at the posterior capsule, long surgical time, frequent neurovascular complications, restricted range of motion and weight-bearing during post-operation rehabilitation [1, 15, 32, 43]. The advancement of all-inside devices allows more complex and stronger meniscus repair. For example, Beamer et al. [6] used a meniscus repair device to pass sutures vertically through the meniscus, which works similarly to the Knee Scorpion device used in our study. They found that single vertical suture repair showed better fixation than single horizontal loop repair carried out by inside-out technique [6]. Similar to the findings of Beamer et al’s study, the double vertical technique in our study employed two vertically oriented suture threads and yielded stronger fixation than the double horizontal technique. It also had a mean failure load and stiffness that were more than twice the values of the single vertical sutures in Beamer et al’s study [6]. Furthermore, compared to the double horizontal cross configuration in the study by Matsubara et al. (which yielded a ultimate failure load of 78.9 ± 19.3 N and stiffness of 8.0 ± 1.5 N/mm) and the cross tie-grip technique that deploys parallel sutures but modified configurations in the study by Nakanishi et al. (which yielded a ultimate failure load of 154.9 ± 29.0 N) [28, 30], our double vertical and double vertical cross configuration yielded much stronger repair and better fixation. We reason that the double vertical and double vertical cross techniques both employ vertical stitches that are perpendicular to the radial fibrils, thus binding them more tightly at the site of tear [6].

The Hybrid configuration composed of one vertical loop at the superior level and one horizontal loop at the inferior level, which had comparable strength to the Double Vertical and Double Vertical Cross, but stronger and stiffer than the Double horizontal technique. In the Hybrid configuration, two loops of sutures form a 90-degree cross inside the meniscus and provide three dimensional primary stabilities against rotatory forces in more complex physiological conditions. However, this was not able to be confirmed in our study, due to the fact that the mechanical testing was limited to the axial force loaded on a single plane.

The primary stability of the repaired meniscus is the most important goal to achieve in successful meniscal repair [28]. To achieve this goal, Herbort et al. [20] found that double-loop horizontal sutures in radial meniscus lesion repair showed greater failure load, less gap formation, and provided stiffer construct than single-loop horizontal suture repair. Matsubara et al. [28] showed that the two horizontal sutures loops forming a cross were biomechanically superior to double horizontal sutures technique in radial meniscus lesion repair. They proved that sutures oblique to circumferential collagen fibrils showed better fixation than those parallel to circumferential fibrils. Current literature emphasizes the importance of suture orientation, number of suture loops, fixation location in radial meniscus lesion repair, given available instruments. The two repair techniques that we proposed in this study integrated the elements contributing to a stronger repair construct and the results of biomechanical testing supported that vertical sutures offered better primary stability supported by the microarchitecture of meniscus. In general, we found that adding vertical sutures significantly improved the strength of the repair construct, because, as speculated by Beamer et al., vertical suture loop perpendicular to the radial tear effectively encircles the radial collagen fibrils [6]. Thus, sutures oblique to the circumferential fibrils are able to resist higher forces.

Furthermore, in the hybrid technique, the horizontal suture loop is practically easier to perform than vertical suture and it can be carried out by either inside-out or outside-in approach. Especially in the anterior or posterior corner of the joint, it is difficult for the vertical suture device to repair the tear.

The gap formation in current study did not differ significantly across all four groups, which was not found in previous studies with similar settings [6, 28, 33]. It may be because the knots were tied very tightly using a knot pusher in our study. The loading force and number of cycles of the cyclic adopted from previous studies did not produce gaps large enough to detect differences across different groups.

Unlike previous studies that various failure modes were reported [6, 20, 24, 33], tissue failure was uniformly noted in our study, which showed that the suture material selected was strong and knots were secure. Furthermore, in this study we only used medial menisci for a better control of the confounding factors. Compared to lateral meniscal tear, the medial meniscus has a higher risk of injuries, because the medial meniscus is attached more tightly to the joint capsule and surrounding tissues, especially the posterior horn is even less mobile, thus more susceptible to injury [31, 44].

Our study has several limitations. Although porcine menisci are similar in shape and function with human, the tissue is not a perfect surrogate. Porcine menisci are thicker, denser and smaller than human menisci and thus may not reflect accurate biomechanical properties [6, 21]. The porcine menisci were harvested from same-aged pigs allowing testing its biomechanical behaviors in a standardized fashion. Thus, we can exclude the confounding factors of highly variable degenerative menisci from the cadaver donors. Previous studies used porcine menisci and found it a good biomechanical model [20, 34, 36, 38]. The study aimed to study the biomechanical properties of repair techniques for radial meniscal lesion. To eliminate confounding factors, a complete radial tear was made and axial force perpendicular to the tear was applied. However, this setting did not reflect the physiological conditions, in which compression, tension, and shear forces apply to the meniscus simultaneously. Furthermore, the repair knots were tied by hands in an open fashion uniformly for all specimens, consequently very small gaps formed after the completion of cyclic loading. This study design simulates the immediate post-operation rehabilitation, where there is no healing and the repair is more vulnerable to damage. Despite that all three techniques showed significantly higher strength and stiffness, it is still unknown that to what degree strength and stiffness of the repaired construct will yield ideal clinical outcomes.

Conclusion

The two techniques for repairing radial meniscus tear developed and proposed – the double vertical cross and the hybrid suture techniques, as well as the double vertical suture, are superior than the conventional double horizontal repair technique in terms of strength and stiffness.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

DH:

Double horizontal

DV:

Double vertical

DVX:

Double vertical cross

References

  1. Ahn JH, Wang JH, Oh I (2004) Modified inside-out technique for meniscal repair. Arthroscopy 20(Suppl 2):178–182

    Article  PubMed  Google Scholar 

  2. Allen CR, Wong EK, Livesay GA, Sakane M, Fu FH, Woo SLY (2000) Importance of the medial meniscus in the anterior cruciate ligament-deficient knee. J Orthop Res 18:109–115

    Article  CAS  PubMed  Google Scholar 

  3. Allen P, Denham R, Swan A (1984) Late degenerative changes after meniscectomy. Factors affecting the knee after operation. J Bone Joint Surg Brit 66:666–671

  4. Aşçi M, Balta O, Kurnaz R, Eren MB, Kuyucu YE, Güneş T (2018) “Horizontal butterfly” technique in repair of radial meniscus tears: a biomechanical study. Acta Orthop Traumatol Turc 52:392–396

    Article  PubMed  PubMed Central  Google Scholar 

  5. Barber FA, Herbert MA, Schroeder FA, Aziz-Jacobo J, Sutker MJ (2009) Biomechanical testing of new meniscal repair techniques containing ultra high-molecular weight polyethylene suture. Arthroscopy 25:959–967

    Article  PubMed  Google Scholar 

  6. Beamer BS, Masoudi A, Walley KC, Harlow ER, Manoukian OS, Hertz B et al (2015) Analysis of a new all-inside versus inside-out technique for repairing radial meniscal tears. Arthroscopy 31:293–298

    Article  PubMed  Google Scholar 

  7. Bedi A, Kelly NH, Baad M, Fox AJ, Brophy RH, Warren RF et al (2010) Dynamic contact mechanics of the medial meniscus as a function of radial tear, repair, and partial meniscectomy. J Bone Joint Surg Am 92:1398–1408

    Article  PubMed  Google Scholar 

  8. Bhatia S, Civitarese DM, Turnbull TL, LaPrade CM, Nitri M, Wijdicks CA et al (2016) A novel repair method for radial tears of the medial meniscus: biomechanical comparison of transtibial 2-tunnel and double horizontal mattress suture techniques under cyclic loading. Am J Sports Med 44:639–645

    Article  PubMed  Google Scholar 

  9. Borden P, Nyland J, Caborn DN, Pienkowski D (2003) Biomechanical comparison of the FasT-fix meniscal repair suture system with vertical mattress sutures and meniscus arrows. Am J Sports Med 31:374–378

    Article  PubMed  Google Scholar 

  10. Branch EA, Milchteim C, Aspey BS, Liu W, Saliman JD, Anz AW (2015) Biomechanical comparison of arthroscopic repair constructs for radial tears of the meniscus. Am J Sports Med 43:2270–2276

    Article  PubMed  Google Scholar 

  11. Buckley PS, Kemler BR, Robbins CM, Aman ZS, Storaci HW, Dornan GJ et al (2019) Biomechanical comparison of 3 novel repair techniques for radial tears of the medial meniscus: the 2-tunnel Transtibial technique, a “hybrid” horizontal and vertical mattress suture configuration, and a combined “hybrid tunnel” technique. Am J Sports Med 47:651–658

    Article  PubMed  Google Scholar 

  12. Chang HC, Nyland J, Caborn DN, Burden R (2005) Biomechanical evaluation of meniscal repair systems: a comparison of the meniscal viper repair system, the vertical mattress FasT-fix device, and vertical mattress ethibond sutures. Am J Sports Med 33:1846–1852

    Article  PubMed  Google Scholar 

  13. Choi N-H, Kim T-H, Son K-M, Victoroff BN (2010) Meniscal repair for radial tears of the midbody of the lateral meniscus. Am J Sports Med 38:2472–2476

    Article  PubMed  Google Scholar 

  14. Cooper D, Arnoczky S, Warren R (1991) Meniscal repair. Clin Sports Med 10:529–548

    Article  CAS  PubMed  Google Scholar 

  15. Diduch DR, Ferguson RE Jr, Tadje JP, Edlich RF (1999) Innovative techniques in arthroscopic meniscal repair. J Long-Term Eff Med Implants 9:367–376

    CAS  PubMed  Google Scholar 

  16. Doig T, Fagan P, Frush T, Lovse L, Chen C, Lemos S (2020) The all-inside all-suture technique demonstrated better biomechanical behaviors in meniscus radial tear repair. Knee Surg Sports Traumatol Arthrosc. https://doi.org/10.1007/s00167-020-06078-2.

  17. Faul F, Erdfelder E, Lang AG, Buchner A (2007) G*power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39:175–191

    Article  PubMed  Google Scholar 

  18. Harper KW, Helms CA, Lambert HS III, Higgins LD (2005) Radial meniscal tears: significance, incidence, and MR appearance. Am J Roentgenol 185:1429–1434

    Article  Google Scholar 

  19. Hendler RC (1984) Arthroscopic meniscal repair. Surgical technique. Clin Orthopaedics Related Res 190:163–169

  20. Herbort M, Siam S, Lenschow S, Petersen W, Zantop T (2010) Strategies for repair of radial tears close to the meniscal rim--biomechanical analysis with a cyclic loading protocol. Am J Sports Med 38:2281–2287

    Article  PubMed  Google Scholar 

  21. Joshi MD, Suh JK, Marui T, Woo SL (1995) Interspecies variation of compressive biomechanical properties of the meniscus. J Biomed Mater Res 29:823–828

    Article  CAS  PubMed  Google Scholar 

  22. Kidron A, Thein R (2002) Radial tears associated with cleavage tears of the medial meniscus in athletes. Arthroscopy 18:254–256

    Article  PubMed  Google Scholar 

  23. Kim Y-M, Rhee K-J, Lee J-K, Hwang D-S, Yang J-Y, Kim S-J (2006) Arthroscopic pullout repair of a complete radial tear of the tibial attachment site of the medial meniscus posterior horn. Arthroscopy 22:795 e791-795. e794

    PubMed  Google Scholar 

  24. Lee YH, Nyland J, Burden R, Caborn DN (2012) Cyclic test comparison of all-inside device and inside-out sutures for radial meniscus lesion repair: an in vitro porcine model study. Arthroscopy 28:1873–1881

    Article  PubMed  Google Scholar 

  25. Lynch MA, Henning CE, Glick KR Jr (1983) Knee joint surface changes: long-term follow-up meniscus tear treatment in stable anterior cruciate ligament reconstructions. Clin Orthop Relat Res (1976-2007) 172:148–153

    Google Scholar 

  26. Makris EA, Hadidi P, Athanasiou KA (2011) The knee meniscus: structure–function, pathophysiology, current repair techniques, and prospects for regeneration. Biomaterials 32:7411–7431

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  27. Massey P, McClary K, Parker D, Barton RS, Solitro G (2019) The rebar repair for radial meniscus tears: a biomechanical comparison of a reinforced suture repair versus parallel and cross-stitch techniques. J Experimental Orthopaedics 6:1–8

    Article  Google Scholar 

  28. Matsubara H, Okazaki K, Izawa T, Tashiro Y, Matsuda S, Nishimura T et al (2012) New suture method for radial tears of the meniscus: biomechanical analysis of cross-suture and double horizontal suture techniques using cyclic load testing. Am J Sports Med 40:414–418

    Article  PubMed  Google Scholar 

  29. Mehta VM, Terry MA (2009) Cyclic testing of 3 all-inside meniscal repair devices: a biomechanical analysis. Am J Sports Med 37:2435–2439

    Article  PubMed  Google Scholar 

  30. Nakanishi Y, Hoshino Y, Nagamune K, Yamamoto T, Nagai K, Araki D et al (2020) Radial meniscal tears are best repaired by a modified “cross” tie-grip suture based on a biomechanical comparison of 4 repair techniques in a porcine model. Orthopaedic J Sports Med 8:2325967120935810

    Article  Google Scholar 

  31. Ozkoc G, Circi E, Gonc U, Irgit K, Pourbagher A, Tandogan RN (2008) Radial tears in the root of the posterior horn of the medial meniscus. Knee Surg Sports Traumatol Arthrosc 16:849–854

    Article  PubMed  Google Scholar 

  32. Pujol N, Panarella L, Selmi TA, Neyret P, Fithian D, Beaufils P (2008) Meniscal healing after meniscal repair: a CT arthrography assessment. Am J Sports Med 36:1489–1495

    Article  PubMed  Google Scholar 

  33. Ramappa AJ, Chen A, Hertz B, Wexler M, Grimaldi Bournissaint L, DeAngelis JP et al (2014) A biomechanical evaluation of all-inside 2-stitch meniscal repair devices with matched inside-out suture repair. Am J Sports Med 42:194–199

    Article  PubMed  Google Scholar 

  34. Richards DP, Barber FA, Herbert MA (2005) Compressive loads in longitudinal lateral meniscus tears: a biomechanical study in porcine knees. Arthroscopy 21:1452–1456

    Article  PubMed  Google Scholar 

  35. Rosso C, Kovtun K, Dow W, McKenzie B, Nazarian A, DeAngelis JP et al (2011) Comparison of all-inside meniscal repair devices with matched inside-out suture repair. Am J Sports Med 39:2634–2639

    Article  PubMed  Google Scholar 

  36. Seil R, Rupp S, Jurecka C, Georg T, Kohn D (2003) Biodegradable meniscus fixations: a comparative biomechanical study. Rev Chir Orthop Reparatrice Appar Mot 89:35–43

    CAS  PubMed  Google Scholar 

  37. Seil R, Rupp S, Kohn DM (2000) Cyclic testing of meniscal sutures. Arthroscopy 16:505–510

    Article  CAS  PubMed  Google Scholar 

  38. Song EK, Lee KB (1999) Biomechanical test comparing the load to failure of the biodegradable meniscus arrow versus meniscal suture. Arthroscopy 15:726–732

    Article  CAS  PubMed  Google Scholar 

  39. Stehling C, Souza RB, Hellio Le Graverand MP, Wyman BT, Li X, Majumdar S et al (2012) Loading of the knee during 3.0T MRI is associated with significantly increased medial meniscus extrusion in mild and moderate osteoarthritis. Eur J Radiol 81:1839–1845

    Article  PubMed  PubMed Central  Google Scholar 

  40. Stender ZC, Cracchiolo AM, Walsh MP, Patterson DP, Wilusz MJ, Lemos SE (2018) Radial tears of the lateral meniscus—two novel repair techniques: a biomechanical study. Orthopaedic J Sports Med 6:2325967118768086

    Article  Google Scholar 

  41. Szczesny SE, Lee CS, Soslowsky LJ (2010) Remodeling and repair of orthopedic tissue: role of mechanical loading and biologics. Am J Orthop (Belle Mead NJ) 39:525–530

    Google Scholar 

  42. Tissakht M, Ahmed A, Chan K (1996) Calculated stress-shielding in the distal femur after total knee replacement corresponds to the reported location of bone loss. J Orthop Res 14:778–785

    Article  CAS  PubMed  Google Scholar 

  43. Turman KA, Diduch DR (2008) Meniscal repair: indications and techniques. J Knee Surg 21:154–162

    Article  PubMed  Google Scholar 

  44. Vedi V, Williams A, Tennant SJ, Spouse E, Hunt DM, Gedroyc WM (1999) Meniscal movement. An in-vivo study using dynamic MRI. J Bone Joint Surg Br 81:37–41

    Article  CAS  PubMed  Google Scholar 

  45. Zantop T, Eggers AK, Musahl V, Weimann A, Hassenpflug J, Petersen W (2004) A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation. Knee Surg Sports Traumatol Arthrosc 12:317–324

    PubMed  Google Scholar 

  46. Zantop T, Eggers AK, Musahl V, Weimann A, Petersen W (2005) Cyclic testing of flexible all-inside meniscus suture anchors: biomechanical analysis. Am J Sports Med 33:388–394

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors thank AM-ETHOS Duke-NUS Medical Student Research Funding (MSRF) for providing financial support for the study and Arthrex for loaning the meniscus repair devices.

Funding

This study was funded by a grant from AM-ETHOS Duke-NUS medical student research fund.

Author information

Authors and Affiliations

Authors

Contributions

GH conceived the study, designed the study, collected data and draft the manuscript. AKSY, CSM, YRW, SCT and DTTL provided substantial inputs in the study design, technical support and revision of the manuscript. The author(s) read and approved the final manuscript.

Corresponding author

Correspondence to Guanqi Hang.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hang, G., Yew, A.K.S., Chou, S.M. et al. Biomechanical comparison of vertical suture techniques for repairing radial meniscus tear. J EXP ORTOP 7, 77 (2020). https://doi.org/10.1186/s40634-020-00296-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40634-020-00296-w

Keywords