Skip to main content

Table 1 Load values in newtons (N) for 5.0 mm of displacement

From: The role of the medial plate for Pauwels type III femoral neck fracture: a comparative mechanical study using two fixations with cannulated screws

Specimen G1
(2 parallel screws + Pauwels screw)
G2
(2 parallel screws + Pauwels screw + medial plate)
1 703 973
2 739 1204
3 960 1178
4 373 1393
5 527 1235
Mean 660 1197
SD 223 150
  1. Source: Serviço de Ortopedia e Traumatologia Prof. Nova Monteiro, 2017