Skip to main content

Table 1 ICC and p values calculated for axial strains measured across five repeated trials at each load condition, for each region in the AMB

From: Novel quantification of the regional strain distribution in the anterior cruciate ligament in response to simulated loading using micro-CT imaging

Flexion Angle (°) Load Condition Femur Insertion Superior Mid-Substance Inferior Mid-Substance Tibia Insertion Global
ICC p value ICC p value ICC p value ICC p value ICC p value
0 5 Nm IR 0.971 0.233 0.969 0.488 0.999 0.924 0.951 0.411 0.998 0.968
100 N AT 0.934 0.488 0.984 0.661 0.994 0.762 0.948 0.297 0.973 0.738
Pivot Shift 0.892 0.243 0.969 0.202 0.998 0.148 0.962 0.359 0.962 0.359
15 5 Nm IR 0.987 0.966 0.966 0.459 0.986 0.574 0.82 0.63 0.920 0.448
100 N AT 0.999 0.115 0.993 0.061 0.999 0.888 0.835 0.394 1.000 0.799
Pivot Shift 0.999 0.71 0.99 0.685 0.998 0.148 0.985 0.438 1.000 0.124
30 5 Nm IR 0.99 0.045* 0.964 0.171 0.994 0.902 0.919 0.689 0.997 0.032*
100 N AT 0.991a 0.434 0.799a 0.112 0.999a 0.981 0.94a 0.419 0.993a 0.216
Pivot Shift 0.915a 0.981 0.964a 0.172 0.96a 0.025* 0.974a 0.555 0.999a 0.106
  1. IR Internal Rotation, AT Anterior Translation Force
  2. * Post-hoc analysis failed to find significant difference
  3. a case with n = 3