Fig. 2From: An interpretation of intraosseous perfusion physiology and the effect of steroidsFor 21 subjects (41 sites) Fig. 2 shows the initial or basal pressure, IOPb and PPb, the arterial clamp pressure, IOPa and PPa, the venous clamp pressure, IOPv and PPv and the perfusion difference, (IOPv-IOPa) and PPv-PPa. IOPb to IOPa and IOPb to IOPv were significantly different p < 0.0001. Error bars bars SD. Blue – IOP, Red – PPBack to article page