Skip to main content

Table 1 Study characteristics

From: Fixed-loop vs. adjustable-loop cortical button devices for femoral fixation in ACL reconstruction – a systematic review and meta-analysis

Study

(year)

Study design

FLD device

ALD device

Tibial fixation

Patients

Age (mean, SD)

Sex, Males (n, %)

Total

FLD

ALD

FLD

ALD

FLD

ADL

Firat et al. (2014) [14]

Retrospective

Endobutton

ToggleLoc with ZipLoop

Bioderadable screw

78

46

32

28.4 (4.2)

27.7 (4.2)

35 (76)

25 (78)

Boyle et al. (2015) [5]

Retrospective

Retrobutton

TightRope

Staple and interference screw

188

115

73

26.1 (11.0)

25.8 (11.7)

64 (56)

50 (68)

Lanzetti et al. (2016) [25]

Prospective

Endobutton

TightRope

Bioderadable screw

44

22

22

26.1 (3.4)

25.2 (3.6)

16 (73)

17 (77)

Choi et al. (2017) [9]

Retrospective

Endobutton

TightRope

Bioderadable screw

117

67

50

29.9 (11.5)

28.2 (11.6)

55 (82)

41 (82)

Sundararajan (2018) [41]

Retrospective

Endobutton

TightRope

Bioderadable screw

98

44

54

37b,d

33b,d

38 (86)

41 (76)

Pokharel et al. (2018) [33]

Prospective

Endobutton

TightRope

Bioderadable screw

60

30

30

33 (18.2)

31 (20)

26 (87)

24 (80)

Asmussen et al. (2018) [4]

Retrospective

Register-based

Endobutton

ToggleLoc with ZipLoop

Various types

1654

1538

116

26.1d

25.9d

860 (56)

71 (61)

Ranjan et al. (2018) [34]

Prospective

Endobutton

TightRope

Bioderadable screw

102

52

50

28.7 (9.5)

30.4 (7.9)

41 (79)

40 (80)

Ahn et al. (2018) [2]

Retrospective

Retrobutton

TightRope

Bioderadable screw

29

22

17

30.7 (10.6)c

32.6 (10.8)c

39 (81)c

51 (84)c

Sheth et al. (2019) [36]

Prospective

Endobutton

TightRope

Bioderadable screw

62

31

31

30.1 (8.9)

30.8 (6.9)

25 (81)

24 (77)

Ahn et al. (2019) [1]

Prospective

Endobutton

TightRope

Bioderadable screw

79

41

38

32 (8.2)

31.2 (10.8)

31 (76)

29 (76)

Uribe et al. (2020) [43]

Prospective

Endobutton

TightRope

Interference screwa

27

13

24

33.9 (11.2)

31.3 (11.7)

6 (46)

11 (46)

Mohamed et al. (2020) [28]

Prospective

Not described

Not described

Bioderadable screw

60

30

30

27.2 (3.3)

26.9 (2.5)

30 (100)

30 (100)

Ono et al. (2021) [31]

Prospective

Endobutton

TightRope

TightRope

28

13

15

25.2 (9.6)

25.7 (8.4)

6 (46)

8 (53)

Djordjevíc et al. (2021) [11]

Prospective

VersiTomic G-Lok

TightRope

Bioderadable screw

60

30

30

27.9 (6.9)

26.9 (6.4)

26 (87)

27 (90)

  1. aThree patients received an ALD for tibial fixation
  2. bDescribed as “average age” in the study
  3. cPatient characteristics measured before lost to follow-up
  4. dStandard deviations not available