Skip to main content

Table 2 Summary of the repeated measures experimental design for each single (S) knee

From: Anterior cruciate ligament microfatigue damage detected by collagen autofluorescence in situ

Specimen

Mechanical fatigue loading and CLEM imaging sequence

S1

Image → 5 preloading cycles → tibial avulsion → dissect → image

S2

Image → 5 preloading cycles → 4 cycles (>  3-mm ATT) → image

S3

Image → 5 preloading cycles → image → 33 cycles → image → 45 cycles → image

S4

Image → 5 preloading cycles → 33 cycles → image → 66 cycles → image → 100 cycles → image

  1. ATT denotes anterior tibial translation