Type of tensile strength | Double modified Kessler technique (Group 1) | Continuous double knots technique (Group 2) | P-value(p) |
---|---|---|---|
Ultimate strength (N) | 25.90 ± 7.11 (n = 20) | 34.56 ± 6.60 (n = 20) | p ≤ 0.001* |
Cyclic testing to failure (cycles) | 88 ± 47.87 (n = 20) | 189 ± 66.36 (n = 20) | p ≤ 0.001* |