Skip to main content

Table 4 Results of the AHI, ROM and clinical scores

From: Effectiveness of measuring tension during arthroscopic rotator cuff repair

  Healed group (n = 111) Failed group (n = 7) p value
Pre AHI, mm 9.4 ± 1.9 9.4 ± 2.1 0.860
Post AHI, mm 11.7 ± 2.2 11.1 ± 4.1 0.913
p value  < 0.001* 0.098  
Pre flexion, ° 125.9 ± 34.0 139.3 ± 33.2 0.193
Post flexion, ° 157.1 ± 12.1 127.9 ± 35.9 0.003†
p value  < 0.001* 0.567  
Pre ER,° 56.8 ± 17.1 56.4 ± 12.8 0.755
Post ER, ° 57.2 ± 16.0 52.9 ± 12.2 0.313
p value 0.647 0.376  
Pre IR, spine level Th11.7 ± 2.9 Th12.5 ± 2.9 0.648
Post IR, spine level Th10.0 ± 2.5 Th11.7 ± 2.9 0.846
p value  < 0.001* 0.486  
Pre constant score 48.4 ± 14.9 54.0 ± 18.0 0.288
Post constant score 83.3 ± 11.9 65.2 ± 23.3 0.008†
p value  < 0.001* 0.315  
Pre UCLA score 14.8 ± 4.3 17.0 ± 5.9 0.342
Post UCLA score 32.6 ± 3.2 23.1 ± 9.2 0.002†
p value  < 0.001* 0.140  
Pre NRS 6.6 ± 1.8 7.0 ± 2.1 0.663
Post NRS 0.9 ± 1.3 3.1 ± 2.6 0.005†
p value  < 0.001* 0.013*  
  1. *Statistically significant between the pre- and post-operative values (p < 0.05)
  2. Statistically significant between the healed and failed groups (p < 0.05)