Skip to main content

Table 1 MRI images of the phantom of 12 different acquisitions have been registered with three different methods

From: Low-field magnetic resonance imaging offers potential for measuring tibial component migration

Acquisition (Reference acquisition)

medial-lateral migration(mm)

distal-proximal migration(mm)

posterior-anterior migration(mm)

flexion-extension migration (deg)

external-internal migration (deg)

varus-valgus migration (deg)

MMRI-M

1 (2)

−0.367

1.657

0.129

−1.460

0.984

0.557

2 (3)

0.241

−1.313

−0.446

0.682

0.681

1.846

3 (4)

−0.158

0.711

−0.535

0.829

−0.107

−0.960

4 (5)

0.857

−0.209

0.359

−1.183

0.386

−0.952

5 (6)

−0.258

−0.116

−0.424

1.623

−0.080

2.125

6 (7)

0.912

0.426

−0.428

2.272

1.039

−0.748

7 (8)

−0.724

−0.525

0.885

−3.657

−0.109

−1.624

8 (9)

−0.146

1.334

−0.699

0.518

0.570

0.456

9 (10)

−0.084

−1.207

−0.295

−1.197

−1.780

−0.821

10 (11)

1.231

−0.372

0.985

0.775

0.712

0.291

11 (12)

0.135

0.516

−0.118

0.465

0.781

0.301

12 (1)

−0.105

−0.642

−0.833

0.939

−1.252

−0.398

μ(σ)

0.128 (0.584)

0.022 (0.931)

−0.118 (0.593)

0.050 (1.630)

0.152 (0.884)

0.006 (1.147)

MMRI-A

1 (2)

0.288

−0.561

1.836

1.506

0.936

−1.022

2 (3)

1.571

−2.674

−2.178

2.964

0.900

6.187

3 (4)

−0.738

3.648

0.381

−2.857

0.298

−3.799

4 (5)

−0.040

−2.650

−0.001

0.952

−0.840

1.247

5 (6)

−1.006

−1.651

−1.670

−4.091

−0.321

3.394

6 (7)

1.210

0.226

1.094

1.968

1.573

−3.264

7 (8)

1.489

0.986

0.597

2.472

1.206

−1.856

8 (9)

−2.071

0.131

−0.667

−5.606

−1.682

0.943

9 (10)

−0.568

2.232

−0.203

1.584

−4.138

2.737

10 (11)

0.535

0.079

0.495

0.628

1.160

−0.290

11 (12)

1.565

−1.566

−1.880

2.888

0.125

3.453

12 (1)

−0.470

1.964

1.167

−2.522

0.393

−7.439

μ(σ)

0.147 (1.172)

0.014 (1.974)

−0.086 (1.284)

−0.010 (2.952)

−0.033 (1.595)

0.024 (3.774)

MMRI-W

1 (2)

−0.326

−0.173

1.702

1.725

−0.779

−0.735

2 (3)

1.315

−0.736

−1.071

−0.359

1.727

0.665

3 (4)

0.094

0.356

−0.081

2.417

0.516

−0.291

4 (5)

0.467

−0.804

0.716

−0.789

−0.416

0.502

5 (6)

−0.432

2.489

−1.456

−2.723

−0.360

−0.305

6 (7)

1.229

−3.267

0.182

4.319

0.750

0.416

7 (8)

0.196

0.690

−0.240

−2.665

0.295

0.291

8 (9)

0.369

1.619

−0.062

2.500

0.206

−0.068

9 (10)

−2.113

1.378

0.618

−3.284

−2.317

−1.114

10 (11)

0.577

−1.102

−0.718

0.452

0.553

0.383

11 (12)

1.669

0.119

−1.792

1.847

1.364

2.007

12 (1)

−1.414

−0.956

0.746

−2.623

−1.781

−1.790

μ(σ)

0.136 (1.100)

−0.032 (1.518)

−0.121 (1.012)

0.068 (2.527)

−0.020 (1.189)

−0.003 (0.967)

  1. This table shows the migration calculated using the MRI data of each acquisition with respect to the previous acquisition
  2. A perfect registration result would be zero migration