Table 7 Factor K p from 2D finite element analysis

From: Mechanical strength assessment of a drilled hole in the contralateral cortex at the end of the open wedge for high tibial osteotomy

Cases Specimens ELL (Nm) PLL (Nm) K p
H SNH 2.6 8 3.2
SWHE 3.5 8 2.3
SWHA 3.5 8 2.3
M SNH 2.1 6.5 3.2
SWHE 2.8 6.5 2.3
SWHA 2.8 6.5 2.3
L SNH 1.7 5.1 3.2
SWHE 2.2 5 2.3
SWHA 2.2 5.1 2.3