Skip to main content

Table 1 Repeatability of cup migration as signed and absolute values from RSA double-examinations (n = 38 double examinations)

From: Superior bone fixation of conical compared with hemispherical trapezial cup design: an experimental radiostereometry study

 

Signed translations

Absolute translations

 
 

x

y

z

x

y

z

TT

Mean differencea

0.001

-0.001

-0.001

0.021

0.023

0.039

0.031

Precisionb

0.053

0.062

0.105

0.032

0.042

0.072

0.066

Min. difference

-0.055

-0.100

-0.150

0.000

0.000

0.001

0.000

Max. difference

0.060

0.085

0.145

0.060

0.100

0.150

0.146

  1. Numbers are reported as translation in mm
  2. amean difference between double examinations (systematic error)
  3. bprecision was calculated as 1.96 × SD (random error)
  4. TT Total translation